Before processing with xTool X1, please complete the initial calibration first. The whole process of initial calibration varies based on the kit that you bought:
Kit that includes | Only the main unit | Main unit + 20W diode galvo module | Main unit + 20W diode galvo module + galvo source |
|---|---|---|---|
Calibration process |
|
|
|
|
| ||
|
The following instructions take the "main unit + 20W diode galvo module + galvo source" kit as an example.
Prepare before calibration
Before calibration, ensure that you've connected xTool X1 with xTool software.
Step 1: Watch the introduction video

Step 2: Install all laser modules and click "All installed"
- The 55W CO2 laser module is pre-installed.
- If you've bought the 20W diode galvo module, install it according to xTool X1 20W Diode Galvo Module User Guide.
- If you've bought the galvo source, install it according to xTool X1 Galvo Source User Guide.

Step 3: Confirm the light source according to the laser modules you've installed and click "Confirm"

Step 4: Confirm whether the field lens installed is correct and click "installed"
Note: For more information about field lens, visit Install and Recognize the Field Lens.

Step 5: Prepare accessories for calibration and click "Done"
Accessories mentioned are included in the package of xTool X1.

Step 6: Click "Preparation done, start calibration"
Note: The calibration fixture/laser calibration tool is included in the galvo source package. The galvo source needs to be purchased separately.

Step 7: Clear the baseplate of xTool X1 and click "Cleared"

Step 8: Close the lid of xTool X1 and click "Closed"

Step 9: Click "Next"

Start basic calibration
The three calibration tasks in this category are performed automatically and take about 5 minutes.
Step 1: Start vibration suppression calibration
Note: As this calibration may cause relatively intense vibration of your xTool X1, do not place any items on or besides the device.

Step 2: Start dot laser full-range calibration

Step 3: Start baseplate leveling

Step 4: Click Next to proceed to the next calibration task

Align CO2 optical path
Step 1: Watch the introduction video

Step 2: Prepare the masking tape and click "Done" and "Next"
Note: The masking tape is included in the xTool X1 package.

Step 3: Adjust the mirror
- Click Move to make the laser module travel to a proper position your can work with.

- Open the lid of xTool X1.
- Follow the video instructions to apply masking tape to the 55W CO2 laser module properly and click Applied.

Note:
- Do not leave any gap between the tape if you want apply two.
- Make sure the tape covers the round hole fully.
- The round hole position of the 55W CO2 laser module is shown in the following image.

- Close the lid of xTool X1.
- Click Done to fire the laser.

- Open the lid of xTool X1 to check the burn mark.
- Check the burn mark on the tape.
- If the burn mark is at the center of the round hole, click Centered.
- If the burn mark isn't at the center of the round hole, click Not centered.

- (Only when the burn mark is not centered)
- Slightly turn the knobs on the right side of the device to adjust the light path.
- Remove the previous tape and apply a new one.
- Close the lid and fire the laser again.
- Open the lid to check if the burn mark is centered.
- If yes, click Centered and move on to the next step.
- If not, repeat these four steps until the burn mark is centered.

- Remove the masking tape covering the round hole and click Masking tape removed in xTool software. Then, click Next.

Align backpack optical path (for the galvo source)
Visit for details.
Calibrate focus (for the 20W diode galvo module)
Visit Calibrate the Focus for xTool X1 for details.

Perform coordinate calibration
Step 1: Watch the introduction video

Step 2: Prepare accessories shown in the software
Both calibration sheet and masking tape are included in the xTool X1 package.

Step 3: Calibrate the cameras
- Open the lid of xTool X1.
- Follow the video instructions and place the calibration sheet on the baseplate and make sure it's secured. Then click Placed.

- Close the lid, click Measure in xTool software, click the start/stop button on the device to start the measurement.



- The camera calibration is performed automatically, you can watch the real-time view inside the device in the software.
Note: Do not open the lid during calibration.

Step 4: Calibrate the flight galvanometer
The flight galvanometer calibration is performed automatically, you can watch the real-time view inside the device in the software.
For more instruction details, visit Flight Galvanometer Calibration.
Note:
- This calibration is for the 20W diode galvo module and the galvo source. If you haven't bought or installed these two modules, this calibration will not be included in the initial calibration.
- Do not open the lid during calibration.

Step 5: Remove the calibration sheet to finish the whole initial calibration
- Open the lid of xTool X1.
- Remove the calibration sheet and click Removed in xTool software.
- Click Finish.

Note:
- If you need to go through the initial calibration again, you can restart the process by clicking Device settings icon > Calibration > Restart near Initialization Calibration.
- You may also perform a particular calibration task in subsequent operations if you've changed a laser module or installed a certain module. You can start the particular calibration by clicking Device settings icon > Calibration > Start near the target calibration task.

Related links
- Before using the 5W UV galvo source to process a glass material, follow Calibrate the Glass Focus for xTool X1 to perform the calibration.
- In subsequent use, if you need to perform certain calibration again, visit: