#1 "No TF card is detected in the device. Please insert the TF card, restart the machine, and try again."

Problem:

Solutions:

1. Power off D1 Pro, reinstall the TF card, and try again.

2. Replace the TF card with another in case it is damaged and try again.

 

#2 "The device has been moved."

Problem:

Solutions:
1. Place the machine on a steady and flat surface, avoiding tilting or shaking.
2. Turn off  Stops when moved if necessary.

V2.1 or later
V1.7 or before
V1.7 or before

 

#3 "A flame is detected."

Problem:

Solutions:

1. Click on the gear icon and select Low sensitivity for the Flame alarm.

V2.1 or later
V1.7 or before
V1.7 or before

2. Set a lower Power and/or Density value, and/or set a higher Speed value when processing on an inflammable material.

3. Replace the Flame Sensor in case it is malfunctioning.

Note: Do not use the machine under direct sunlight or accent light.

 

#4 "The laser module has moved over the position limit."

Problem:

Solutions:

1. Check and make sure the ends of the limit switch cable are connected properly.

2. Check and make sure the limit switch sensor is not contaminated.

3. Replace the limit sensor(s) in case it was malfunctioning.

4. Turn off the Limit switch if necessary.

V2.1 or later
V1.7 or before
V1.7 or before
Preview
Was this page helpful?
5 out of 8 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Copyright © 2024 xTool All Rights Reserved.
Call Us
Telephone
Pre-sales : +1(970)638-7030
After-sales : +1(775)587-7760
Email
Pre-sales : vicky@info.xtool.com
After-sales : support@info.xtool.com
Service Time
Mon-Fri : 7:00 am - 5:30 pm (PT)
Sat-Sun : 8:30 am - 5:30 pm (PT)
Copyright © 2024 xTool All Rights Reserved.