xTool X1 User Guide
Updated Oct 29,2026
Updated Oct 29,2026

List of items

Note: The actual appearance of the power cable may vary.

1 主机.png

2 电源线.png

3 USB 线.png

4 旋转附件线.png

5 钥匙.png

xTool X1

Power cable

USB cable

Extension cable for xTool rotary attachment

Key

6 烟管组件.png

7 防冻液.png

8 两用螺丝刀.png

9 一字螺丝刀.png

10 美纹胶.png

Exhaust duct assembly

Antifreeze

2-in-1 screwdriver (Phillips + hex)

Slotted screwdriver

Masking tape

11 刀条.png

12 对焦卡.png

14 对焦纸.png

15 材料固定销.png

16 旋转附件固定销.png

Slat

Focus calibration card

Calibration sheet

Material pin

Rotary attachment fixing pin

17 网框固定件.png

18 测距贴片.png

19 窗口镜安装工具.png

PixPin_2026-10-28_19-11-40.png

PixPin_2026-10-28_19-12-25.png

Frame fixing pin

Patches for distance measurement (spare parts)

Installation tool for optical window

Nozzle

Lubricant

20 椴木版.png

21 安全说明.png

22 快速使用指南.png



Basswood

Safety Instructions

Quick Start Guide



Meet xTool X1

Note:

1. Do not place objects in front of the air outlet, as this may affect heat dissipation.

2. The laser input path has a dust-proof sticker. If a galvo source is not used, keep the sticker to avoid contaminating the optical path.

00结构1.png

① Lid

② Exhaust fan

③ CO₂ laser module

④ Emergency stop button

⑤ Steering mirror mount for CO₂ laser

⑥ Flame monitoring camera

⑦ Motor

⑧ Rotary attachment port

⑨ Conveyor feeder port

⑩ Annular indicator

⑪ Start/Stop button

⑫ Base up button

⑬ Base down button

PixPin_2026-10-28_19-52-39.png

⑭ Steering mirror mount for galvo source

⑮ Distant-view camera

PixPin_2026-10-28_19-53-54.png

⑯ USB port

⑰ Port for key

⑱ Extension port

⑲ Galvo source port

⑳ Water level window

㉑ Water tank

㉒ Air outlet

㉓ Laser input path

㉔ Presence sensor for galvo source

㉕ Power port for galvo source

㉖ Power port for main unit

㉗ Power switch

Preparations

Note:

1. Place xTool X1 on a flat and clean surface to prevent small particles from being drawn into the air inlet at the device bottom, which may reduce the device performance or cause damage.

2. Reserve sufficient space behind xTool X1 for subsequent operation such as liquid filling and exhaust duct assembly installation.


1. Remove the limit blocks and cable ties

26 限定块和扎带.png

(1) Cut the cable ties.

PixPin_2026-10-28_19-13-17.png

Note: Be careful not to damage the timing belt when cutting the cable ties.

PixPin_2026-10-28_19-13-33.png

(2) Remove the two stickers behind the cable ties.

(3) Pull out the x-aixs guide rail and remove the limit blocks.

28.png

2. Peel off the masking tape on the CO₂ laser module

Note: When peeling off the tapes, the cover plate and the nozzle of the laser module may become detached. Simply reattach them magnetically.

PixPin_2026-10-28_19-15-48.png

3. Install the nozzle

PixPin_2026-10-28_19-16-44.png

(1) Fit the air tube of the CO2 laser module onto the nozzle.

PixPin_2026-10-28_19-17-22.png

Note: Fit the air tube all the way to ensure it is fully seated.

PixPin_2026-10-28_19-18-13.png

(2) Magnetically attach the nozzle to the nozzle holder inside the laser module. After installation, gently tug on the air tube to make surethe nozzle is securely seated.

Note: Once the nozzle is magnetically securedin place, it is normal for the tube to bend.No action is required.

PixPin_2026-10-28_19-19-22.png

PixPin_2026-10-28_19-22-04.png

4. Insert the key

30.png

5. Check the emergency stop button

Ensure that the emergency stop button is released. If it is pressed, rotate to release it as shown in the image.

31 emergency button.png

Note: If an emergency occurs, you can press the emergency stop button to shut off the machine.

32 emegency stop button2.png

After dealing with the emergency, you can turn the emergency stop button to reset it.

6. Fill the water tank

Note:

Temperature-related:

■ It is recommended to operate the device in an ambient temperature range of 0°C to 35°C. Please avoid using the device in temperatures below -10°C, as this could result in permanent damage.

■ Do not use antifreeze when the ambient temperature is 0°C or above. Otherwise, it will reduce heat dissipation performance.

■ When the ambient temperature rises from below 0°C to 0°C or above, drain all liquid from the water tank and fill it with the recommended amount of purified water.

33 processing.png

■ Fill the water tank before powering on the device to prevent the laser tube from freezing and cracking.

■ To avoid overflow, be careful when pouring in liquid.

■ Distilled water or deionized water may be used as substitutes for purified water, but never use mineral water, tap water, or other liquids as substitutes.

■ The provided antifreeze is 99.8% propylene glycol. Store it in a cool, well-ventilated area away from heat sources and avoid direct sunlight.

(1) Determine the volumes of antifreeze and purified water to be used based on the annual lowest temperature in your region.

Annual lowest temperature in your region (°C)

Concentration (%)

Antifreeze (mL)

Purified water (mL)

T≥0

0

0

1300

-10≤T<0

20

260

1040

-20≤T<-10

35

455

845

-30≤T<-20

45

585

715

* After adding the appropriate amout of liquid as shown in the table above, the liquid level should reach the "FULL" mark.

(2) Open the water tank cap.

34 open water cap.png

(3) Fill the water tank (Take –8°C as an example).

Refer to the table in step (1). In the example environment of –8°C, 260 mL of antifreeze needs to be added.

PixPin_2026-10-28_19-26-00.png

36.png

Then, fill in 1040 mL purified water.

37.png

(4) Tighten the water tank cap.

7. Install the exhaust duct assembly

(1) Remove the four screws securing the smoke exhaust fan.

38.png

(2) Install the exhaust duct assembly with the four screws removed in step (1).

39.png

Note:

xTool X1 has now been fully installed. If the kit also includes 20W diode galvo module or a galvo source, refer to the corresponding User Manual to complete the remaining installation steps. Make sure both the main unit and all accessories are fully installed before proceeding to initial calibration and processing operations in xTool software.

41.png

42.png

User Manual of 20W Diode Galvo Module

User Manual of Galvo Source

8. Plug in the power cable and power on the device

40.png

Note: Make sure you add the recommended amount of antifreeze and purified water into the water tank before connecting the device to a power supply.

Use xTool X1

1. Get the xTool software

Go to s.xtool.com/software to get the xTool software.

43.png

2. Connect xTool X1 to a computer

Note: The other end of the USB cable can be connected to a USB Type-A or Type-C port. Choose between the connectors based on your needs.

45.png

PixPin_2026-10-28_19-28-45.png

For details about how to use xTool software to operate xTool X1 for material processing, visit support.xtool.com/3123.

Note: After connecting the device in xTool software, follow the on-screen instructions to complete the initial calibration first.

Secure a material / accessory

Note: Three fixing items are included in the xTool X1 package for different scenarios. Use them as required.

Scenario 1: Secure a material

(1) Install slats or a honeycomb panel. (The honeycomb panel needs to be purchased separately. The following steps use slats as an example.)

46.png

(2) Place the material and secure it by snapping the material pins on the slats.

47.png

Scenario 2: Secure the rotary attachment

(1) Install the rotary attachment fixing pins.

48.png

(2) Install the rotary attachment.

Note: The following steps take xTool Rotary Attachment 3 as an example. Before installing, assemble the rotary attachment according to its user manual.

49.png

To connect xTool rotary attachment with xTool X1, use the connection cable of the rotary attachment and the extension cable of xTool X1 together.

50.png

(1) Connect the two cables.

51.png

(2) Plug the extension cable into the rotary attachment's port and the connection cable into the corresponding port on xTool X1.

52.png

Scenario 3: Secure the frame of xTool Screen Printer

(1) Install the frame fixing pin.

53.png

(2) Insert the frame with screen attached.

Note: Before inserting the frame, ensure that you’ve mounted the screen on the frame according to the user manual of xTool Screen Printer, and that the frame is facing the correct direction.

54.png

Indicator and buzzer description


Annular indicator

Buzzer

Device status

55.png

Blinking white

/

Initializing

56.png

Breathing white

/

Sleeping

57.png

Solid white

One beep

Standby, connected to the network

58.png

Blinking blue

/

Configuring network

59.png

Solid blue

/

Standby, not connected to the network

60.png

Blinking yellow

/

Framing

61.png

Solid yellow

/

Automated operations, such as automatic distance measurement and photo capture

62.png

Blinking green

/

Processing

63.png

Solid green

One beep

Ready to process

/

Task paused

64.png

Blinking red for three times

Three consecutive beeps

Exceptions occur

64.png

Blinking red

Keeping buzzing

Serious exceptions occur

65.png

Blinking purple

/

Calibrating

66.png

Solid purple

/

Firmware updating

Maintenance

Note: Power off the device before maintenance.

67.png

Clean the lens protector of the CO₂ laser module

Note: Avoid getting the lens protector dirtyduring any operation. If it becomesdirty, clean it promptly.

68.png

Lubricate the motors

PixPin_2026-10-28_19-34-46.png

If the device produces noticeable unusual noise, apply lubricating oil to the four motors to keep them operating smoothly. Applyabout two drops of lubricating oil into the center screw hole of each motor.

PixPin_2026-10-28_19-35-16.png


Clean the exhaust fan

(1) Remove the exhaust duct assembly.

69.png

(2) Disconnect the connectors and take out the fan.

70.png

(3) Use a brush or other tools to clean the fan.

Note: Do not rinse or immerse the fan in water.

71.png


(4) Connect the connectors and reinstall the fan.

Note: Ensure the fan logo faces outward when reinstalling.

73.png

72.png

Note: After installing the fan, arrange the cables properly to avoid overbending.

74.png

(5) Reinstall the exhaust duct assembly.

75.png

Preview
Was this page helpful?
4 out of 4 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
xTool Logo

Contact Us

🇺🇸+1 (833) 588-4887
Service Live Chat

Copyright © 2026 xTool All Rights Reserved.