xTool Rotary Attachment 3 Lite User Guide
Updated Nov 13,2026
Updated Nov 13,2026

Note: xTool Rotary Attachment 3 Lite is an accessory designed exclusively for xTool M2. It is used with xTool M2 to process rotating workpieces.

ra3_lite_中文线上帮助文档封面图.jpg

Purchase link: RA3 Lite for M2

Download PDF file (multi-language)

xTool Rotary Attachment 3 Lite (RA3 Lite) Quick Start Guide

English - Quick Start Guide

Deutsch - Kurzanleitung

Español - Guía de inicio rápido

Français - Guide de démarrage rapide

Italiano - Guida rapida

Nederlands - Korte handleiding

Português - Manual de referência rápida

Polski - Skrócona instrukcja obsługi

日本語 - クイックガイド

한국어 - 빠른 시작 가이드

资源 1@2x-100.jpg

ภาษาไทย - คู่มือเริ่มต้นการใช้งาน

资源 2@2x-100.jpg

Tiếng Việt - Hướng dẫn bắt đầu nhanh

资源 3@2x-100.jpg

Bahasa Melayu - Panduan Mula Pantas

资源 4@2x-100.jpg

Bahasa Indonesia - Panduan Mulai Cepat

繁體中文 - 快速入門指南

简体中文 - 快速使用指南

Links to the video tutorial and article for using xTool M2 with RA3 Lite

Video


Article: Use xTool Rotary Attachment 3 Lite with xTool M2

Safety precautions

  • The product features a magnetic quick-release design. Do not put your hand between magnetic parts during use to avoid pinching yourself. There is also a risk of pinching when assembling different modules, rotating the jaw chuck, and adjusting the power module and the support module.
  • Keep the product away from children.
  • Clean the product using a dry cloth.

Note: Click here for multi-language safety instructions.

List of items

Unbox xTool Rotary Attachment 3 Lite and check the items inside the pack. If you find items missing or broken, please contact us for after-sales support.

Part name

Image

Jaw chuck

image.png

Cylindrical jaw

image.png

T-shaped jaw

image.png

Extended jaw

image.png

Power module

image.png

Main baseplate

image.png

Support module

image.png

Stud components

image.png

Laser shield

image.png

Horizontal laser emission holder

image.png

Positioning plate

image.png

Device connection cable

image.png

Tape measure

image.png

Select clamping accessories and methods

Select the appropriate accessories based on the workpiece shape, diameter, and actual clamping requirements.

Note: The data in the table below applies only to horizontal laser emission mode. In this mode, RA3 Lite supports workpieces up to 100 mm in diameter when used with M2. Vertical laser emission mode is used when M2 is equipped with the riser base. Refer to xTool M2 Riser Base Kit User Guide for the applicable workpiece diameter ranges in vertical laser emission mode.

Workpiece type / examples

Recommended diameter range

Clamping accessories

Notes

Cylindrical workpieces / small straight tumblers, champagne flutes, pens, and thin rods

3–60 mm

Extended jaws

If the workpiece diameter is ≤ 55 mm, do not install the support module, as the laser module may collide with it.

Cylindrical workpieces / straight tumblers and tapered tumblers without handles

60–80 mm

Cylindrical jaws

The support module can be installed if needed.

Cylindrical workpieces / Stanley-style tumblers, mugs, and large or handled cups

80–100 mm

Cylindrical jaws + T-shaped jaws

The support module can be installed if needed. If the handle is detachable, it is recommended to remove it before processing.

Spherical workpieces / Christmas ornaments and baseballs

30–100 mm

Cylindrical jaws

The support module must be installed. Its installation orientation differs from that used for cylindrical workpieces.

Ring-shaped workpieces / Rings and bracelets

10–100 mm

Stud components

Only the outer surface of the workpiece can be processed.

Use xTool Rotary Attachment 3 Lite

Preparations

1. Fix the power module on the main baseplate.

image.png

image.png

2. Assemble the jaw chuck components according to the workpiece and the selected jaws.

image.png

  • Method 1: Suitable for common rotating workpieces (using cylindrical jaws only)

image.png

  • Method 2: Suitable for large-diameter rotating workpieces with smooth surfaces (using cylindrical jaws and T-shaped jaws)

Note: In horizontal laser emission mode, RA3 Lite supports workpieces up to 100 mm in diameter when used with M2.

image.png

  • Method 3: Suitable for small-diameter, lightweight rotating workpieces (using extended jaws only)

Note: In horizontal laser emission mode, RA3 Lite supports workpieces up to 100 mm in diameter when used with M2.

image.png

Process cylindrical objects

image.png

Note: The workpiece diameter range shown above (d ≤125 mm) applies only to vertical laser emission mode. In horizontal laser emission mode, RA3 Lite supports workpieces up to 100 mm in diameter when used with M2.

1. Put the workpiece on a table. Place the jaw chuck against the workpiece as illustrated, with its jaws surrounding the outside of the workpiece.

image.png

2. Rotate the knob to secure the workpiece.

image.png

3. Insert the jaw chuck components into the power module.

image.png

4. Rotate the jaw chuck components until you hear a click.

image.png

Note: To remove the jaw chuck from the power module, hold the jaw chuck firmly and pull it straight out.

Note: If the workpiece diameter is ≤55 mm, do not install the support module, and skip steps 5–7 to prevent the laser module from colliding with it.

5. Slide the support module into the main baseplate.

image.png

6. Rotate the knob clockwise to hold the support module in position.

image.png

7. Rotate the knob to adjust the height of the two wheels on the support module until they touch the workpiece.

image.png

Note: If the workpiece is long, there are two methods to use the support module.

Method 1: Slide the support module into the main baseplate and hold it in position

image.png

Method 2: Place the support module outside the main baseplate

image.png

The following are common application scenarios for using extended jaws, as well as simultaneously using cylindrical jaws and T-shaped jaws.

  • Extended jaws: Primarily suitable for processing rotating workpieces up to 60 mm in diameter. It is recommended to mount the extended jaws in the middle or the innermost holes of the jaw chuck.

image.png

Warning: If other jaws are mounted in the middle or the innermost holes of the jaw chuck, the laser module may collide with the jaw chuck or other components during processing.

image.png

  • Cylindrical jaws + T-shaped jaws: It is recommended to mount them in the outermost holes of the jaw chuck.

image.png

If the workpiece is a mug with a handle, it is recommended to use cylindrical jaws and T-shaped jaws to secure the mug. Refer to the following illustration for the recommended handle placement.

image.png image.png image.png

- A handle placed too high may collide with the lid of xTool M2 during processing.

- A handle placed too low may collide with the main baseplate of RA3 Lite during processing.

- An overly long handle may collide with the front plate of xTool M2 where the Start/Stop button is located.

- Before processing, use the Framing function in xTool Studio to check whether the handle interferes with surrounding parts during movement. If the handle is detachable, it is recommended to remove it before processing. If you need to keep the handle attached, make sure that the sum of the cup body diameter and the handle width at its widest point does not exceed 130 mm, and that the handle does not interfere with surrounding parts during framing.

image.png

Process spherical objects

image.png

Note: The workpiece diameter range shown above (d ≤130 mm) applies only to vertical laser emission mode. In horizontal laser emission mode, RA3 Lite supports workpieces up to 100 mm in diameter when used with M2.

1. Insert the assembled jaw chuck components into the power module.

image.png

2. Rotate the jaw chuck components until you hear a click.

image.png

Note: To remove the jaw chuck from the power module, hold the jaw chuck firmly and pull it straight out.

3. Place one side of the workpiece against the jaws.

image.png

4. Slide the support module into the main baseplate in the orientation shown, with its bell mouth against the other side of the workpiece.


image.png

5. Rotate the knob clockwise to hold the support module in position.

image.png

Process rings and bracelets

Tip: The following steps apply to both rings and bracelets, using a ring as an example. For a bracelet, install the stud components in the appropriate mounting holes and turn the knob to secure the bracelet.

Note: In horizontal laser emission mode, RA3 Lite supports workpieces up to 100 mm in diameter when used with M2.

image.png

1. Install the stud components.

image.png

2. Place the ring onto the stud components.

image.png

3. Rotate the knob to secure the ring.

image.png

4. Insert the jaw chuck into the power module.

image.png

5. Rotate the jaw chuck until you hear a click.

image.png

Note: To remove the jaw chuck from the power module, hold the jaw chuck firmly and pull it straight out.

Use with xTool M2

1. Press the power switch of xTool M2 to turn off the device.

image.png

image.png

2. Remove the module connection cable.

image.png

3. Remove the laser module.

image.png

4. Attach the horizontal laser emission holder to the multi-function module holder.

image.png

image.png

5. Install the laser shield to the laser module.

Note: For the 10 W, 20 W, or 40 W laser module, install the laser shield as illustrated. For the 3 W laser module, installation of the laser shield is not necessary.

image.png

image.png

6. Attach the laser module to the horizontal laser emission holder.

image.png

7. Connect the laser module to the device using the module connection cable.

image.png

8. Position the assembled power module and main baseplate close to the center of the device.

image.png

9. Insert one end of the device connection cable into the port on the back of the power module.

image.png

搭配使用步骤九.jpg

10. Place the positioning plate in the bottom-right corner inside the device.

image.png

搭配使用步骤十.jpg

11. Move xTool Rotary Attachment 3 Lite next to the positioning plate, ensuring it is placed securely against the plate.

image.png

12. Place the other positioning plate on the other side of the main baseplate.

image.png

image.png

13. Install the workpiece onto xTool Rotary Attachment 3 Lite.

image.png

14. Secure the device connection cable to the cable clamps, and insert the other end into any extension port on the device.

image.png

Note: If you have not removed the sticker from xTool M2 extension ports, remove it first, then insert the other end of the device connection cable into any extension port.

image.png

15. Close the lid.

image.png

Note: After closing the lid, always check whether the device connection cable is correctly led through the notch in the lid. If it is not positioned properly, open the lid and adjust the cable to ensure it is not squeezed.

image.png

16. Download and install the xTool software. Turn on xTool M2. Open the software and connect your M2, then follow the on-screen instructions to complete the remaining steps. For detailed instructions, see Use xTool Rotary Attachment 3 Lite with xTool M2.

More information

xTool M2 User Guide

Preview
Was this page helpful?
120 out of 123 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
xTool Logo

Contact Us

🇺🇸+1 (833) 588-4887
Service Live Chat

Copyright © 2026 xTool All Rights Reserved.