xTool M2 CMYK Inkjet Module User Guide
Updated May 27,2026
Updated May 27,2026

Download PDF file (multi-language)

英语 EN.jpg

德语 DE.jpg

西班牙语 ES.jpg

法语 FR.jpg

English_User Manual

Deutsch_Benutzerhandbuch

Españo_Manual del usuario

Français_Manuel de l'utilisateur

意大利语 IT.jpg

荷兰语 NL.jpg

葡萄牙语 PT.jpg

波兰语.png

Italiano_Manuale d'uso

Nederlands_Gebruikershandleiding

Português_Manual do utilizador

Język Polski_Podręcznik użytkownika

日语 JA.jpg

韩语 KO.jpg

th.png

vi.png

日本語_ユーザーマニュアル

한국어_사용자 설명서

ภาษาไทย_คู่มือการใช้งาน

Tiếng Việt_Hướng dẫn sử dụng

ms.png

id.png

繁中 ZH-TW.jpg

简中 ZH.jpg

Bahasa Melayu_Manual pengguna

Bahasa Indonesia_Panduan pengguna

繁體中文_使用者手冊

简体中文_用户手册

Safety instructions

  • Recommended operating environment:

Operating temperature: 15-35°C (59°F – 95°F)

Operating humidity: 40-60% RH

  • Do not store the ink cartridge in environments with drastic temperature or humidity changes, or in high-temperature/high-humidity areas.
  • Keep the ink cartridge and the module out of reach of children.
  • Avoid direct sunlight exposure to the ink cartridge.
  • Do not touch the metal contacts or the ink nozzle on the cartridge.
  • Do not peel off the labels on the side of the ink cartridge.
  • Do not install or remove the ink cartridge while the device is powered on.
  • Ink is not edible.
  • If ink contacts the skin or eyes, rinse immediately with plenty of water. Seek medical attention if discomfort persists.

List of items

01 模组.png

02 ink.png

03 bottom cap.png

xTool M2 CMYK Inkjet Module

Ink cartridge

Bottom cap

04 moisturizing liquid.png

05Bottom cap retainer plate.png

06 Screw.png

Moisturizing liquid

Bottom cap retainer plate

Screw

07 Calibration card.png

磁环.png

08 User GUIDE.png

Calibration card (A5)

Ferrite core

User manual

Install the ink cartridge

Prepare the ink cartridge

(1) Take out the ink cartridge.

09 takeout.png

(2) Peel off the protective film.

10-2 peeloff.png

Note: DO NOT touch the metal contacts on the bottom of the ink cartridge.

11 note_触点.png

Open the front cover

12 front cap.png

Install the ink cartridge

(1) Align the ink cartridge with the inner track of xTool M2 CMYK Inkjet Module. Gently push the cartridge in at approximately a 45° angle.

13 install cartridge.png

Note:

DO NOT insert the cartridge vertically, as this may cause jamming.

DO NOT force the installation. If you encounter resistance, adjust the angle and try again.

15 notecartridge.png

(2) Once the cartridge is fully inserted, press it inward gently. You will hear a "click" sound when the cartridge is properly installed.

14 installationdone.png

Close the front cover


16 closefrontcap.png

Install the bottom cap

Attach the bottom cap to the bottom of xTool M2 CMYK Inkjet Module, ensuring it is magnetically secured in place.

17 install bottom cap.png

  • The bottom cap is secured to the module via built-in magnets
  • Material thickness determines whether it can be processed with the inkjet module.
    • Material thickness > 2.6 cm: Processing not supported.
    • 2 cm ≤ Material thickness ≤ 2.6 cm: Manually remove the bottom cap.
    • Material thickness < 2 cm: Manual removal of the bottom cap is not required.

Install xTool M2 CMYK Inkjet Module

Before installing xTool M2 CMYK Inkjet Module, make sure:

■ xTool M2 is turned off.

■ Any other modules are removed from xTool M2.

■ Laser module calibration has been completed in xTool software.

Install the bottom cap retainer plate

(1) Align the bottom cap retainer plate with the reserved mounting hole on the upper-left side of xTool M2's baseplate.

18 bottom cap retainer plate.png

19 align.png

(2) Use a hex screwdriver to securely fasten the retainer plate.

20-2 included.png

Install the inkjet module

Attach xTool M2 CMYK Inkjet Module to the multi‑function holder of xTool M2, ensuring it is magnetically secured in place.

21 install module.png

Note: The module attaches to the multi-function holder via built-in magnets.

Connect xTool M2 and the inkjet module

连接设备物料-en.png

(1) Attach the ferrite core to the module connection cable.

安装磁环.png

(2) Connect xTool M2 CMYK Inkjet Module to the multi-function module holder via the module connection cable.

安装连接线.png

Maintenance and care

Moisturizing sponge

The bottom cap contains a built-in moisturizing sponge. Add moisturizing liquid (or purified/distilled water) regularly.

Principle: Keep the sponge moist. Avoid overfilling or accumulation of liquid.

Excessive liquid may cause color mixing at the ink nozzle or printing issues.

23-2 保湿海绵.png

Cleaning sponge

The bottom cap also contains a cleaning sponge. Remove and clean it regularly.

  • Rinse the sponge with clean water to remove residual ink.
  • Wring out excess water and reinstall the sponge directly—complete drying is not required.

24-2 cleaning.png

Cleaning frequency:

Before use: Check if the sponge is dirty.

Extended downtime: Clean at least once per month.

Regular operation: Adjust cleaning frequency based on inkjet usage intensity. Excessive ink buildup without timely cleaning may affect print quality.

Ink nozzle

Avoid exposing the ink nozzle to air for extended periods.

  • If residual ink or dust is present on the nozzle surface, gently wipe it with a lint-free cloth (not included).

26.png

Related links

Preview
Was this page helpful?
4 out of 5 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
xTool Logo

Contact Us

🇺🇸+1 (833) 588-4887
Service Live Chat

Copyright © 2025 xTool All Rights Reserved.