xTool P2S User Guide
Updated Sep 30,2024
Updated Sep 30,2024

Download PDF files (multi-language)

English_xTool P2S_Quick start guide

Deutsch_xTool P2S_Kurzanleitung

Español_xTool P2S_Guía de inicio rápido

Français_xTool P2S_Guide de démarrage rapide

Italiano_xTool P2S_Guida rapida

Nederlands_xTool P2S_Korte handleiding

Português_xTool P2S_Manual de referência rápida

日本語_xTool P2S_クイックガイド

한국어_xTool P2S_빠른 시작 가이드

繁體中文_xTool P2S_快速入門指南

中文简体_xTool P2S_快速使用指南

 

List of items

xTool P2S

Power cable

USB cable (Type-C)

Key (spare part)

Smoke exhaust pipe components

Antifreeze

Funnel

Basswood 3 mm

Transparent acrylic

Screwdriver

Hex key

Material clamp

Screw M3*6 (spare parts)

Screw M3*22 (spare part)

Self-Check Guide

Quick Start Guide

Safety Instructions

 

Open the box and take out all the items

1. Open the lid and take out the items.

2. Remove the thumb screws and brackets at the left and right ends of the x-axis guide rail.

3. Move the x-axis guide rail forward and take out the foam.


4. Unscrew the screw that fixes the baseplate.


5. Take out the foam and acrylic sheets and put the baseplate back to the machine.


6. Tighten the screw that fixes the baseplate.

Meet your xTool P2S

Understand the indicator and state display screen

Annular indicator

Screen

Device

Blinking white

/

Starting

Solid white

Displays the temperature and lid locked/unlocked state

Standby, not connected

Solid white

Displays the icon of the connection mode

Standby, connected

Breathing green

/

Sleeping

Blinking blue and then solid blue

/

Ready to work

Solid blue

Progress bar blinks and moves

Performing a task

Solid blue

Progress bar stops moving

Task paused

Solid green

/

Task completed

Solid white

/

Task canceled

Solid purple

/

Firmware updating

Solid red

Fault indicator lit up

Exceptions occur

/

H or L lit up

Liquid temperature alarm

H: Temperature too high

L: Temperature too low

Breathing blue

/

Calibrating or image recognizing

Solid red

/

Calibration or recognition failed. You can open and then close the lid or use XCS to bring the device back to the standby state.

Solid yellow

/

Waiting for AP network setting.

You can hold down the button on xTool P2S for 5 seconds to start AP network setting. If no network is set within 2 minutes, the device goes back the standby state.

Name of the AP hotspot: XTOOL-P2S-Last 6 digits of MAC address

Note: "/" indicates no state change.

State display screen

1. Progress bar, where you can see the progress of a processing task
2. Lid locked/unlocked
Do not open the lid forcibly when it is locked. You can press the button on the machine to unlock the lid before opening it.

3. The machine is connected through Wi-Fi.
4. The machine is connected through the USB cable.
5. Exceptions occur.
6. Liquid temperature

H: lighting up indicates that the temperature is too high

L: lighting up indicates that the temperature is too low.

Preparations

💡 Do not connect the machine to a power supply until you are instructed to.

1. Check the casing of the machine. If it is severely damaged, do not use the machine and contact xTool after-sales services.

2. Remove the sticker used to prevent the lid from locking and turn the emergency stop switch to reset it.

3. Check the access-control key. Ensure that it is inserted in place.

💡 The key can function as both an access control key and an interlock connector. Go to xTool Access Control Key to learn more.

4. Manually move the laser module to check whether it can move properly. If it can't, do not use the machine and contact xTool after-sales services.

5. Check the laser tube. If it is cracked or damaged, do not use the machine and contact xTool after-sales services.

(1) Unscrew the screws that fix the rear cover and remove it.

(2) Check whether the laser tube is cracked or damaged.

6. Fill the water tank with antifreeze. 

You need to prepare a measuring glass to measure purified water.

If you can't find a measuring glass at home, you can store the antifreeze in another container and use the bottle of the antifreeze to measure purified water.

Note:

■ Determine the volume of antifreeze to be used according to the annual lowest temperature in your region first.

■ Ensure that you use purified water to prepare the antifreeze. Tap water contains impurities and bleach, which may cause too many bubbles, affecting the working of the laser tube and even damaging the laser tube.

■ You need to fill the water tank twice. Strictly follow the steps to fill the water tank, using the recommended volume of antifreeze and avoiding overflow.

(1) Determine the volumes of antifreeze and purified water to be used.

  • If the annual lowest temperature in your region >0°C

Annual lowest temperature in your region (℃)

Concentration (%)

First filling

Second filling

Antifreeze (ml)

Purified water (ml)

Purified water (ml)

T >0

0

0

1100

300

  • If the annual lowest temperature in your region ≤ 0°C

Annual lowest temperature in your region (℃)

Concentration (%)

First filling

Second filling

Antifreeze (ml)

Purified water (ml)

Purified water (ml)

–10 ≤ T ≤ 0

20

280

820

300

–20 ≤ T ≤ –10

35

490

610

300

–30 ≤ T ≤ –20

45

630

470

300

–40 ≤ T ≤ –30

50

700

400

300

–50 ≤ T ≤ –40

60

840

260

300

(2) Open the cap of the water tank and insert the funnel into the opening.

(3) Complete the first filling.

Pour the required volume of antifreeze into the water tank, and then slowly pour the required purified water in. Observe the water level during the filling to avoid overflow.

(4) Connect the machine to a power supply and turn on the machine.

(5) Complete the second filling.

Wait 30s for the water level to descend in the water tank, pour the required purified water in, and then close the cap of the water tank. Observe the water level during the filling to avoid overflow.

(6) Fit the rear cover back to the machine and tighten the screws.

(7) Install the smoke exhaust pipe.

💡 If you have purchased a smoke purifier, follow the instructions to connect it to xTool P2S.

Use xTool P2S

You can use the xTool official software xTool Creative Space (XCS) to operate xTool P2S. For details, see "Use XCS to operate xTool P2S".

 

 

Preview
Was this page helpful?
6 out of 7 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Copyright © 2024 xTool All Rights Reserved.
Call Us
Service Time
Mon-Fri,9:00-18:30 PDT
Pre-sales Hotline
+1(970)638-7030
Customer Service Hotline
+1(775)587-7760
Email Us
Service Time
Mon-Fri,9:00-18:30 PDT
Pre-sales and shipping related
vicky@info.xtool.com
vicky@xtool.com
After-sales and shipping related
support@info.xtool.com
support@xtool.com
Technical Support
support@info.xtool.com(US)
support@xtool.com(US)
support.eu@xtool.com(EU)
support.uk@xtool.com(UK)
Brand Cooperation
If you want to cooperate with
xTool on causes like education,
public welfare, innovation, etc.,
or if you want to review our
machines, please email
partner@xtool.com
US headquarter
XTL US INC. 16035 Arrow Hwy.
Irwindale. CA91706
Copyright © 2024 xTool All Rights Reserved.