Poor Performance in Fire Extinguishing of Fire Safety Set
Updated Dec 20,2023
Updated Dec 20,2023

Issue Description:

When P2 is correctly installed with a fire safety set, and you want to do a fire extinguishing test, or P2 catches fire during processing, you may find little or no carbon dioxide gas ejected from the vent hole. This may result in a failure to extinguish the fire or an unsatisfactory fire-extinguishing effect.

 

#1 Check the Air Tube of the Fire Safety Set for Kinks

  1. Check the external air tube of the fire safety set for any kinks and adjust them.
  2. If it can not be adjusted, just cut off the kinked segment and rejoin the ends.

 

#2 Check the Air Tube Connector Inside P2 for Loose Connection

  1. Remove the rear plate of P2 and check the connection of the air tube.
  2. If you find it loose or detached, please reinstall it.

Note: Please make sure not to bend the air tube when reinstalling the rear plate.

 

#3 Check the Air Tube Inside P2 for Kinks

  1. Remove the rear plate of P2 and check the air tube.
  2. If it is kinked, press down the connector of the air tube and take it out.
  3. Cut off the kinked segment and rejoin the ends.

Note: Please make sure not to kink the air tube when reinstalling the rear plate.

 
Preview
Was this page helpful?
0 out of 0 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Copyright © 2024 xTool All Rights Reserved.
Call Us
Service Time
Mon-Fri,9:00-18:30 PDT
Pre-sales Hotline
+1(970)638-7030
Customer Service Hotline
+1(775)587-7760
Email Us
Service Time
Mon-Fri,9:00-18:30 PDT
Pre-sales and shipping related
vicky@info.xtool.com
vicky@xtool.com
After-sales and shipping related
support@info.xtool.com
support@xtool.com
Technical Support
support@info.xtool.com(US)
support@xtool.com(US)
support.eu@xtool.com(EU)
support.uk@xtool.com(UK)
Brand Cooperation
If you want to cooperate with
xTool on causes like education,
public welfare, innovation, etc.,
or if you want to review our
machines, please email
partner@xtool.com
US headquarter
XTL US INC. 16035 Arrow Hwy.
Irwindale. CA91706
Copyright © 2024 xTool All Rights Reserved.