Use the Desktop Smoke Purifier for xTool F1
Updated Jul 13,2024
Updated Jul 13,2024

List of items

Desktop smoke purifier

image__1_.png

Pipe adapter

 

Connection cable for xTool F1

Connection cable for xTool M1 Ultra

image__3_.png

Power adapter & power cable 

 

Filter pack

 

 

Pre-filter

Pipe

 

 

User manual

 

Meet the desktop smoke purifier

1.png

2.png

Install the desktop smoke purifier

1. Install the pipe attached to xTool F1 to the smoke inlet of the smoke purifier.

πŸ’‘ Tips: You can find the component in the pack of xTool F1.

image__9_.png

image__10_.png

2. Install the other end of the pipe to the smoke outlet of xTool F1.

image__11_.png

3. Connect the power cable and power adapter to the power port and the socket.

image__12_.png

4. Connect one end of the connection cable for xTool F1 to the xTool F1 port. And connect the other end to the smoke purifier port.

image__13_.png

 

(Optional) Install the pipe to the smoke outlet of the smoke purifier.

πŸ’‘ Tips: You can decide whether to install the pipe included in the pack of the desktop smoke purifier according to your need.

image__14_.png

How to install the pipe adapter?

To install the pipe adapter, stretch the end of the pipe first, and tighten the pipe adapter to the pipe clockwise.

image__16_.png

Use the desktop smoke purifier

πŸ’‘ Tips: There are 3 levels of power, including low, middle and high.

If the laser module emits blue rays, it is recommended to select the high level. If the laser module emits infrared rays, it is recommended to select the middle or low level.

image__17_.png

Turn on the smoke purifier and select the power level by shifting the level adjustment switch.

 

If you connect the desktop smoke purifier to xTool F1

image__18_.png

United mode: When xTool F1 is detected, the smoke purifier automatically switches to the United mode.

The smoke purifier starts working when xTool F1 starts processing and continues working for a while long after xTool F1 stops processing, so as to purify the air.

The continued working time can be set on the XCS software.

2023-05-19_10-49-14.png

Press: The smoke purifier starts/stops working. When the smoke purifier accepts the united commands from xTool F1, it executes the commands from xTool F1 in priority.

πŸ’‘ For details about how to connect XCS to xTool F1, visit support.xtool.com.

image__19_.png

 

If you disconnect the desktop smoke purifier from xTool F1

πŸ’‘ When the smoke purifier is under the Constant mode and xTool F1 is detected, it automatically switches to the United mode.

image__20_.png

Constant mode: You can only press the button to switch the working status of the smoke purifier when xTool F1 is not detected.

Press: The smoke purifier starts/stops working.

Indicator status description

Indicator status

Buzzer status

Explanation

image__26_.png 

Light on for 3 seconds, and light off

image__30_.png

Three times

The device is powered on.

image__27_.png 

The indicator of the united mode lights on.

image__30_.png

Once

The device is working in united mode.

image__28_.png

The indicator of the constant mode lights on.

image__30_.png 

Once

The device is working in constant mode.

image__29_.png 

Blink rapidly

image__30_.png 

Twice, at an interval of three seconds

The motor has been damaged. Please replace the filters in a timely manner or check whether something is blocking the smoke inlet.

Maintenance

Meet the filter pack

3.png

Replace the filter pack

1. Press two sides of the lid, open the lid and take out the pre-filter.

image__21_.png

2. Hold the strap of two sides up and take out the used filter pack.

image__22_.png

3. Put the new filter pack and pre-filter into the smoke purifier.

πŸ’‘ You can visit www.xtool.com to purchase the filter pack.

4. Close the lid.

πŸ’‘ Tips: Press the lid down and make sure the lid is installed properly.

image__25_.png

FAQs

Problem: Under the United mode, the device is processing, but the purifier does not work. Why and what can I do?

Possible causes: The inlet gets blocked. Or There is something in the pipes. Or One or more filters fail to work after long-term use, which is indicated when the buzzer of the purifier sounds.

Solutions:

- Replace the filter(s). Replaceable filters are used in the product. When the buzzer of the machine sounds, you need to clean or replace the filters for the purifier. You can visit xtool.com to buy the filters you need.

- Power off the purifier, open the lid and check whether the inlet is blocked, and then check whether the outlet is choked.

 
 
Preview
Was this page helpful?
3 out of 3 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day