Set up xTool X1 in xTool Software
Updated Oct 29,2026
Updated Oct 29,2026
After connecting xTool X1 to the software, you can set up xTool X1 by referring to the following steps.
In the top-right corner of the software, click the settings icon.

Basic info
In the Basic info tab, you can view:
- Device name: shows the device name. You can enter the text box to change it.
- Processing model: displays the model being processed.
- Serial number: displays the serial number of your device.
- Firmware version: shows the firmware version. You can click Check for updates to update to the latest version if available.
- Automation model version: displays the automation model version. You can click Check for updates to update to the latest version if available.
- Capture & Trace model version: displays the capture & trace model version. You can click Check for updates to update to the latest version if available.
- Wi-Fi setting: displays the Wi-Fi address.
- Plug-in version: displays the plug-in version of your device. You can click Info to view details about it.

Calibration
In the Calibration tab, you can operate:
- Initialization calibration: guides you through the initialized calibration to eliminate potential errors and ensure first-use accuracy.
- Vibration suppresion calibration: detects device vibration and generates suppression parameters to fix engraving jitter and uneven edges.
- Dot laser full-range calibration: eliminates structural errors.
- Base leveling: measures the height across the work area and calibrates baseplate flatness.
- CO2 optical path alignment: adjusts the reflector lens angles so the laser travels along the center path, fixing optical path offset issues.
- Backpack optical path alignment: adjusts the reflector lens angles so the laser travels along the center path, fixing optical path offset issues.
- Focus calibration: determines the optimal focal distance through tests at different heights to fix blurry, overly thick, or overly thin lines.
- Glass engraving positioning calibration: compensates for potential offset to ensure accurate 3D engraving positioning.
- Camera calibration: builds the mapping between the camera view and the actual processing position to fix pattern offset and alignment issues.
- Flight galvanometer calibration: calibrates the mapping between galvo module scanning and actual coordinates to fix position offset or distortion during high-speed processing.

Device settings
In the Device settings tab, you can view:
- Auto close-up photography in auto mode: enables or disables auto mode during processing.
- Air nozzle presence detection: enables or disables detection for the air nozzle during the device is processing with the 55W CO2 laser module.
- Flame alarm: If enabled, the device pauses processing and raises the alarm when flame is detected. You can switch between high detection sensitivity and low detection sensitivity.
- Smart height compensation: automatically measures
- Buzzer reminders: enables or disables the buzzer of the machine. After being disabled, the buzzer no longer works as an indicator.
- Smart trial run check: If enabled, the device automatically checks for processing marks to prevent device damage from out-of-focus processing.
- Intelligent fill light integration: If enabled, the left and right fill light brightness can be automatically adjusted for multi-segment shooting, therefore improving image quality. If disabled, standard image capture applies.
- Near fill light brightness: If enabled, the close-up image can avoid overexposed circumstance or severe glare.
- High-precision ranging: If enabled, fine measurement in Process on flat surface mode helps to improve accuracy, at the cost of extra time.
- High frequency lens dirt detection: If enabled, this function helps to detect dirt on the lens or nozzle timely to prevent reduced laser powr or laser module damage. You can set Detection interval as needed.
- Low frequency lens dirt detection: If enabled, this function helps to detect dirt on the lens or nozzle timely to prevent reduced laser powr or laser module damage. You can set Detection interval as needed.
- Galvo heatsink dust removal: helps to shake off dust built in the heatsink in about 1 minute after a long relief task.
- Smoke exhaust time: sets the time the smoke exhaust processes takes.
- Smoke fan speed: sets the speed of smoke exhaust fan.
- Airflow of air pump: sets the airflow of the air pump for engraving or cutting tasks.
- Export elements on the canvas as G-code: exports all the elements on the canvas to a G-code file.

Working info
In the Working info tab, you can view:
- Work log: You can click Export to export the work log of the device.
- Working time: displays the total time the device processes materials.
- Operating times: displays the total number of times the device has been operated.
- Standby time: displays the total time the device is on standby.

Accessory information
In the Accessory information tab, you can operate:
- Accessory information: displays the accessory that connects to xTool X1.
- Solutions to Bluetooth accessory connection failures: Click View to see the connection solutions.

Preview
Was this page helpful?
1 out of 1 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day