Issue description
After connecting Rotary Attachment 3 Lite (RA3 Lite) to xTool M2, you may encounter rotation issues, including:
- The RA3 Lite does not rotate smoothly.
- The RA3 Lite does not rotate at all.
- During processing, the rotary axis either does not rotate or rotates intermittently, causing the engraving to appear as a single straight line instead of producing the intended rotary engraving result.
Possible causes
- The RA3 Lite device connection cable is not properly connected.
- The extension port on M2 is malfunctioning.
- The RA3 Lite power module is malfunctioning.
Troubleshooting
Step 1: Check the RA3 Lite device connection cable
(1) Turn off M2 to ensure safety.
(2) Check whether both ends of the connection cable are securely connected to the RA3 Lite and M2.
|
|
Connection port on the RA3 Lite | Connection port on xTool M2 |
(3) Unplug and reconnect the cable. Make sure the connectors are fully inserted.
(4) Check the cable for visible damage, dents, or breaks. If the cable is damaged, replace it.
(5) Turn M2 back on and check whether the RA3 Lite rotates properly.
Step 2: Connect the cable to another extension port on M2
(1) If Step 1 does not resolve the issue, turn off M2. (2) Disconnect the RA3 Lite device connection cable from the current extension port on M2, and connect it to another extension port.
(3) Turn M2 back on and check whether the RA3 Lite rotates properly.
(4) If the issue is resolved after switching ports, the original extension port may be malfunctioning. Please contact our after-sales team to have the mainboard replaced.
Note: If the issue persists after switching ports, proceed to Step 3.
Step 3: Contact xTool Support to replace the RA3 Lite power module
If the RA3 Lite still does not rotate properly after you have tried all the extension ports on the side of M2, the RA3 Lite power module may be malfunctioning. Please contact our after-sales team by submitting a ticket to have the RA3 Lite power module replaced. When contacting us, provide the M2 serial number (SN), which can be found on the back of the device, and a video showing the issue.
Still experiencing issues?
Should the issue persist after completing the preceding steps, submit a ticket via the "Submit a Ticket" button in the "Help Ticket" section below. The standard response time for xTool Customer Service is one business day.
For a prompt resolution, please include the following details:
- Issue description: A detailed explanation of the observed problem.
- Video evidence: Attach a video demonstrating the issue, where applicable.
- Troubleshooting performed: Any troubleshooting steps you have already attempted, along with their results.
This information is crucial for xTool technical support engineers to provide timely assistance.
Documentation feedback
Help improve this content by providing feedback. If this content did not meet your requirements, select "No" in the "Was this page helpful?" section below. Include specific details about what was unclear or missing in the pop-up suggestion box. Feedback submissions are reviewed by xTool technical writers to enhance future documentation.