The device occurs an exception, and a pop-up window indicating a gas cylinder motor error appears even after connecting to the software.
The error code is GAS_BOTTLE_HOME.TIMEOUT.

Update to the latest version of the software and firmware, then restart the device.
(1) Disconnect the device from the power supply. Follow the image below or the tutorial to remove the left panel.

(2) Unplug and plug the connector as shown. Then restart the device.

(1) Disconnect the device from the power supply. Follow the tutorial to remove the rear panel.
(2) After unplugging and reinserting the gas cylinder motor reset sensor connector (as shown), restart the device.

Should the issue persist after completing the preceding steps, submit a ticket via the "Submit a Ticket" button in the "Help Ticket" section below. The standard response time for xTool Customer Service is one business day.
For a prompt resolution, please include the following details:


This information is crucial for xTool technical support engineers to provide timely assistance.
Documentation feedback
Help improve this content by providing feedback. If this content did not meet your requirements, select "No" in the "Was this page helpful?" section below. Include specific details about what was unclear or missing in the pop-up suggestion box. Feedback submissions are reviewed by xTool technical writers to enhance future documentation.