The processing is paused suddenly and cannot continue to process. The software displays a pop-up window. The error code is "COOL_WATER_MACHINE.ELEMENT_ABNORMAL.WATER_LINE_LOW".

Update the firmware and software to the latest version. And then restart the device.
Normally, after the device is turned on, some antifreeze will circulate into the laser tube and water tube, and the level of the remaining antifreeze in the water tank is roughly 70%-80% of the water tank's capacity.

(1) Power off the device and disconnect it from a power supply.
(2) Follow the tutorial to remove the upper cover of the laser tube.
(3) Check whether the interior of the laser tube cracks, causing antifreeze to leak outside the inner tube (The laser tube features a double-walled glass structure. Normally, the antifreeze circulates only inside the inner tube).

(1) Check whether the liquid leaks around the water tank. (This problem is caused by the water level in the water tank dropping in a short period of time after the device leaks.)


If the antifreeze in the water tank is adequate, but the error code still indicates "Low water level", follow the tutorial to replace a new water-cooling system.
Should the issue persist after completing the preceding steps, submit a ticket via the "Submit a Ticket" button in the "Help Ticket" section below. The standard response time for xTool Customer Service is one business day.
For a prompt resolution, please include the following details:

This information is crucial for xTool technical support engineers to provide timely assistance.
Documentation feedback
Help improve this content by providing feedback. If this content did not meet your requirements, select "No" in the "Was this page helpful?" section below. Include specific details about what was unclear or missing in the pop-up suggestion box. Feedback submissions are reviewed by xTool technical writers to enhance future documentation.

Copyright © 2025 xTool All Rights Reserved.