The processing is paused suddenly and cannot continue to process. The software displays a pop-up window.
The error code is COOL_WATER_MACHINE.ELEMENT_ABNORMAL.WATER_FLOW_LOW.

Update the firmware and software to the latest version. And then restart the device.
(1) Check whether the proportion and volume of the antifreeze meet the actual requirements (as the table below).
When its concentration is too high, the water flow speed will decrease. Especially when you pour the whole antifreeze into the tank, the "water flow too low" error code may occur.

(2) If the water flow is too slow, follow step 3 in the tutorial to drain the antifreeze and refill the tank with the correct concentration of antifreeze.
When the device powers on, the water pump keeps working, no matter whether you process or not.


If the water-cooling system is faulty, see the video to replace it.
Should the issue persist after completing the preceding steps, submit a ticket via the "Submit a Ticket" button in the "Help Ticket" section below. The standard response time for xTool Customer Service is one business day.
For a prompt resolution, please include the following details:

This information is crucial for xTool technical support engineers to provide timely assistance.
Documentation feedback
Help improve this content by providing feedback. If this content did not meet your requirements, select "No" in the "Was this page helpful?" section below. Include specific details about what was unclear or missing in the pop-up suggestion box. Feedback submissions are reviewed by xTool technical writers to enhance future documentation.

Copyright © 2025 xTool All Rights Reserved.