Rotary Attachment | Connection cable | Hex key | User guide card |
1: Motor 2: Device connection port 3: Adjustable roller 4: Roller stand 5: Slot × 3 6: Fixed roller |
Gear | Diameter (unit: mm) |
1 | 3-50 |
2 | 45-60 |
3 | 60-70 |
5. Place four risers horizontally or vertically according to the diameter of the cylindrical material.
Diameter (unit: mm) | The way risers should be placed |
3-20 | Horizontally |
20-70 | Vertically |
6. Place the cylindrical material on Rotary Attachment, move Rotary Attachment to position the highest point of the material right on the red light spot, and then close the lid.
7. On xTool Creative Space, Click Camera, drag the yellow line to the highest point of the material and then click Auto-measure.
8. Import a project file or insert an element.
9. Adjust the image size, place the image closely on the right of the yellow line, and then set the parameters: material, speed, power, and pass.
10. Click Start and then click Send.
11. Press the button to start processing.
12. Take out the material after the operation is complete and the ventilator stops working.
1. Turn off xTool M1. Disconnect it from the power supply before you remove the connection cables.
2. Remove the connection cable of Rotary Attachment, detach it from xTool M1 and then install the baseplate.
3. Close xTool Creative Space and open it again. Then its processing mode changes automatically.
State | Description | |
Before operation | Normally on in white | Not connected |
Blinking in green | Network setting | |
Normally on in blue | Connected | |
In operation | Blinking in blue | Performing a task |
Breathing in green | Task completed | |
Breathing in white | Entering the sleep state | |
Other | Blinking in purple | Firmware updating |
Normally on in red | Exceptions occur |