The software prompts "Gantry homing exception" and the error code indicates "GO_HOME.FAILED.Z_AXIS".

Whenever the device is powered on, the air nozzle lowers slowly for a short distance until it reaches the very bottom and then emits an impact noise.

At this time, power off the device. Manually rotate the Z-axis lead screw using a slot-type screwdriver to raise the nozzle. However, this issue will repeat after powering on.

The air nozzle may get stuck in a certain position and emit an impact noise continuously.

At this time, power off the device. Manually rotate the Z-axis lead screw using a slot-type screwdriver to lower the nozzle a bit. However, this issue will repeat after powering on.

⚠️ Safety First: Power off your device before performing the step.
(1) Power off the device.
(2) Follow the tutorial to manually rotate the Z-axis lead screw using a slot-type screwdriver.
(3) Restart the device.

(1) Power off the device.
(2) Remove the cover of the laser module.
(3) Check if the connection cables, as shown, are loose. Unplug and plug them.
(4) Restart the device.

(1) Power off the device.
(2) Remove the fixed screws and protective lens as shown.
(3) Remove the shell of the laser module (Z-axis) upwards.

(4) Use a slot-type screwdriver to adjust the Z-axis up and down (as shown). And observe whether the limit spacer can align and fit in the middle of the limit switch's sensor probe.

According to the steps above, power on the device. Use a slot-type screwdriver to adjust the Z-axis up and down. And observe whether the indicator changes when the limit spacer fits the middle of the probe.

(1) Power off the device and disconnect from a power supply.
(2) Remove the left plate following the steps or the video tutorial.

(3) Check if the connection cable is loose (as shown), and then unplug and plug the cable.
(4) Restart the device.

Should the issue persist after completing the preceding steps, submit a ticket via the "Submit a Ticket" button in the "Help Ticket" section below. The standard response time for xTool Customer Service is one business day.
For a prompt resolution, please include the following details:
This information is crucial for xTool technical support engineers to provide timely assistance.
Documentation feedback
Help improve this content by providing feedback. If this content did not meet your requirements, select "No" in the "Was this page helpful?" section below. Include specific details about what was unclear or missing in the pop-up suggestion box. Feedback submissions are reviewed by xTool technical writers to enhance future documentation.