Cleaning and Maintenance for xTool F2 Ultra
Updated Oct 8,2026
Updated Oct 8,2026

Applicable scenario

Regular cleaning helps ensure consistent laser performance and extends the life of your device. This guide will walk you step-by-step on how to clean your F2 Ultra.

Note: Before performing any maintenance, disconnect the power and remove the safety key to avoid injury or equipment damage.

Clean the field lens

When to clean

  • Engraved patterns are shallow
  • Materials can't be cut as expected

How to clean

  1. Use a lint-free cloth moistened with absolute ethanol
  2. Gently wipe the lens surface to remove dust or residue

Note: Avoid scratching the lens during cleaning.


Clean the fan module

When to clean

  • Smoke leaks from the protective enclosure
  • Exhaust seems weak or airflow is restricted

How to clean

  1. Remove the magnetic fan guard from the smoke outlet.
  2. Open the cover, and then take out the fan module.
  3. Open the cover to reveal the fan.
  4. Use a brush or other tools to clean the fan module and the magnetic fan guard. Then, install them back to the main unit.

Note: DO NOT rinse or immerse the fan module in water, as it may damage the circuit.

Clean the protective enclosure

When to clean

The protective enclosure is dirty.

How to clean

  1. Take a clean, lint-free cloth (such as a microfiber cloth), dampen it with clean water, and wring out any excess water until the cloth is only slightly damp.

Note: Ensure that no water drips from the cloth to prevent liquid from entering the internal components.

  1. Wipe the inside and outside of the protective enclosure evenly.

清洁防护罩.png

Preview
Was this page helpful?
207 out of 210 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
xTool Logo

Contact Us

🇺🇸+1 (833) 588-4887
Service Live Chat

Copyright © 2026 xTool All Rights Reserved.