This procedure should be performed only if you encounter the following situation while using your xTool M1 Ultra:
Before proceeding, ensure that:
Once you have verified these conditions, proceed to write the module's serial number (SN) manually into the machine’s memory.
The method for writing the SN differs depending on your computer's operating system and how it is connected to your M1 Ultra. Choose the appropriate section below:
Step 1: Write SN
YOUR_MODULE_SN_HERE
) with the actual SN from your processing module.http://201.234.3.1:8080/cmd?cmd=M81S2N1C
+ YOUR_MODULE_SN_HERE
+ &dest=35&wait=false
ZH009PBED20-0004
, the complete URL will be: http://201.234.3.1:8080/cmd?cmd=M81S2N1CZH009PBED20-0004&dest=35&wait=false
Step 2: Verify SN
http://201.234.3.1:8080/cmd?cmd=M81S2N0&dest=35&wait=true
{"result":"ok", "value": "M81 CZH009PBED20-0004"}
💡 Note: The SN in the "value" field should match the one you entered.
Step 1: Write SN
http://201.234.4.1:8080/cmd?cmd=M81S2N1C
+ YOUR_MODULE_SN_HERE
+ &dest=35&wait=false
ZH009PBED20-0004
, the complete URL will be: http://201.234.4.1:8080/cmd?cmd=M81S2N1CZH009PBED20-0004&dest=35&wait=false
Step 2: Verify SN
http://201.234.4.1:8080/cmd?cmd=M81S2N0&dest=35&wait=true
{"result":"ok", "value": "M81 CZH009PBED20-0004"}
💡 Note: The SN in the "value" field should match the one you entered.
Step 1: Locate your M1 Ultra IP address
Step 2: Write SN
M1_ULTRA_IP_ADDRESS
) with the IP address you found in XCS.YOUR_MODULE_SN_HERE
) with the actual SN from your processing module.http://
+ M1_ULTRA_IP_ADDRESS
+ :8080/cmd?cmd=M81S2N1C
+ YOUR_MODULE_SN_HERE
+ &dest=35&wait=false
192.168.1.100
and your module's SN is ZH009PBED20-0004
, the complete URL will be: http://192.168.1.100:8080/cmd?cmd=M81S2N1CZH009PBED20-0004&dest=35&wait=false
Step 3: Verify SN
M1_ULTRA_IP_ADDRESS
with your machine's actual IP address) to verify: http://
+ M1_ULTRA_IP_ADDRESS
+ :8080/cmd?cmd=M81S2N0&dest=35&wait=true
{"result":"ok", "value": "M81 CZH009PBED20-0004"}
💡 Note: The SN in the "value" field should match the one you entered.
Note: The method supports writing the SN of laser module only. The multi-function carriage and ink module are not supported.
Step 1: Download the SN Repair
Click the link to download the SN Repair, which is a web tool. Make sure that you have a browser installed on your computer in advance. It is recommended that you use Chrome.
Step 2: Connect the device to the computer
Ensure the device is connected to the computer via USB or Wi-Fi.
Step 3: Get the SN
Select the model of the laser module, then click Get Laser Head SN. SN Repair captures the SN automatically.
Step 4: Start repairing
Enter the SN into the text box, click Repair.
Step 5: Check the result
Writing SN is successful once you see the sentence "Repair request sent successfully".
After successfully writing and verifying the serial number, restart xTool Creative Space software and your M1 Ultra to confirm the laser module is now recognized.
Documentation feedback
Help improve this content by providing feedback. If this content did not meet your requirements, select "No" in the "Was this page helpful?" section below. Include specific details about what was unclear or missing in the pop-up suggestion box. Feedback submissions are reviewed by xTool technical writers to enhance future documentation.
Copyright © 2025 xTool All Rights Reserved.