Power Requirements in Different Regions (800W)
Updated Sep 10,2025
Updated Sep 10,2025

General power requirements

Item

Requirements

Input voltage

200–240 V AC, 50/60 Hz

Full load current

13.5 A

Rated power

3 kW

Circuit protection

20 A air circuit breaker recommended

Regional electricity requirements

United Kingdom

Item

Requirements

Connection type

Use a bare wire terminal or a power plug:

  • Bare wire terminal
    • Cable colors: Brown (L), Blue (N), Yellow-green (PE)
    • Connection: Must be performed by professional electricians
  • Power plug
    • Standard: IEC 60309, 16A, blue, single-phase

Cable

  • 2.5 mm² (or 12 AWG)
  • Current-carrying capacity: 16 A or above

Voltage

  • Rated voltage: 230 V AC
  • Voltage fluctuation range: 207–253 V AC

Australia / New Zealand

Item

Requirements

Plug

  • AS/NZS 3112, 15 A / 20 A

Cable

  • 2.5 mm² (or 12 AWG)
  • Current-carrying capacity: 14 A or above

Voltage

  • 230–240 V AC
  • High-power usage scenario: 5500 W, 230 V, 24 A

South Korea

Item

Requirements

Plug

  • Type F plug (Schuko), IEC 60309, 16 A

Voltage

  • 220 V AC
  • High-power usage scenario: 3000 W, 220 V, 25 A

Japan

Item

Requirements

Plug

  • NEMA L6-20P, 20 A / 250 V

Voltage

  • 220 V AC
  • High-power usage scenario: 3000 W, 200 V, 15 A

Mainland, Hong Kong, Macao, and Taiwan regions of China

Region

Voltage

Plug specification

Mainland China

220 V AC

GB 1002, 16 A

Hong Kong/Macau, China

220 V AC

IEC 60309, 16A, Blue, Single-phase (2P+E)

Taiwan, China

220 V AC

NEMA 6-20P

Safety precautions

  • Qualified installation: Wiring operations must be performed by certified electricians with local qualifications.
  • Independent circuit: To prevent overload and tripping, do not share the power circuit with other high-power devices.
  • Grounding: Ensure the PE (yellow-green wire) is securely connected. If the circuit is not grounded, add a separate grounding wire.
  • Cable specifications:
    • Cross-sectional area 2.5 mm² (or 12 AWG)
    • Insulation temperature rating 90°C

Caution: Do not use household sockets rated below 16 A for power supply.

  • Plug compatibility: Power cables vary by region. Please use the appropriate plug based on your power cable type.

Troubleshooting tips

  • Voltage exception: If the device fails to start, first check if the voltage is within the range of 200–240 V AC.
  • Tripping issue: Ensure that the circuit breaker has a capacity of no less than 20 A and the circuit is not overloaded.




Preview
Was this page helpful?
0 out of 0 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
xTool Logo

Contact Us

Submit a Ticket
🇺🇸+1 (888) 528-2293
Service Live Chat

Copyright © 2025 xTool All Rights Reserved.