xTool Air Compressor User Guide
Updated Nov 26,2025
Updated Nov 26,2025

Download PDF files (multi-language)

English_xTool Air Compressor_Quick Start Guide

Deutsch_xTool Luftkompressor_Kurzanleitung

Español_xTool Compresor de aire_Guía de inicio rápido

Français_xTool Compresseur d’air_Guide de démarrage rapide

Italiano_xTool Compressore dell'aria_Guida rapida

Nederlands_xTool Luchtcompressor_Korte handleiding

Português_xTool Compressor de ar_Manual de referência rápida

Język Polski_xTool Sprężarka powietrza_Skrócona instrukcja obsługi

日本語_xTool エアコンプレッサー_クイックガイド

한국어_xTool 에어 컴프레서_빠른 시작 가이드

繁體中文_xTool 空壓機_快速入門指南

简体中文_xTool 空压机_快速使用指南

Unboxing xTool Air Compressor

List of items

Unbox xTool Air Compressor and check the items inside the pack. If you find items missing or broken, please contact us for after-sales support.

Air compressor



Filters for the silencers (spare)



Tube

Quick start guide

Safety instructions


Meet Air Compressor

Product structure


Product specifications

PSI

145

CFM

12.4

Operating pressure (MPa)

0.3-1.0

Rated power (W)

2200

Tank capacity (L)

20

Operating voltage (VAC)

200–240

Machine net weight (kg)

16

Dimensions (W × H × D) (mm)

460 × 530 × 270

Connections

Since the air compressor is designed to be used with the air dryer and the welder, this manual includes instructions for operating the air dryer. Please find the air dryer components from its package.

1. Connect the devices

2. Connect drain tube

■ Connect the drain tube to the drain outlet and guide the tube to a wastewater disposal area.

3. Connect to power supply


Power requirements:

Air dryer:

- US/Japan: 100–120 VAC

- EU/UK/AU: 200–240 VAC

For other countries and regions, see the requirements on the machine label.

Air compressor: 200–240 VAC


image.png

Use the devices

1. Power on

Power on the air dryer first and then the air compressor.

CAUTION: The air compressor’s upper part heats up during operation. Do not touch it during operation or shortly after it shuts down.

2. Check the safety valve of the air compressor

3. Set pressure

Pressure range: 0.3–1.0 MPa 

Recommended pressure: 1.0 MPa 

Up button: + 0.05 MPa per press 

Down button: –0.05 MPa per press

The air compressor automatically stops working when the air pressure reaches the set value, and starts working again when the pressure drops 0.2 MPa below the set value.

4. Switch the speed mode

Press the FAST/SILENCE button to switch the operating speed. A speed of 99% indicates high-speed mode, while 50% indicates low-speed mode. 

Recommended mode: FAST

 

Once the air compressor's current pressure is steady, you can proceed to operate the welding machine.

Note: To stop the air dryer and compressor, first turn off the air compressor and then turn off the air dryer.

More information

Use with MetalFab machines

Use with xTool MetalFab Machines

Set Up, Use, and Power Off the Air Compressore and Air Dryer

Maintenance

Discharge of waste water

Maintenance After Long-term Use


Preview
Was this page helpful?
0 out of 0 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
xTool Logo

Contact Us

🇺🇸+1 (888) 528-2293
Service Live Chat

Copyright © 2025 xTool All Rights Reserved.