Test and Calibrate the Optical Path for xTool P2 (Important)
Updated Mar 21,2024
Updated Mar 21,2024

Note:
This page provides users with guidance on determining whether the first and second mirrors of xTool P2 work properly and if they don't, how to calibrate them.
In this way, you can ensure that the laser beam reaches the laser module through the third optical path hole.

 

Why you need it

To prevent issues, it's recommended to first test and calibrate the optical path when encountering the following scenarios:

  • Before starting the initial processing task: After you unbox and set up xTool P2 as instructed in the quick start guide, please test the optical path before use to ensure proper material processing.
  • After cleaning/replacing mirrors.
  • When no laser is coming out from the laser module.
  • When there is a noticeable decrease in processing power.

 

Tools you need

The two-in-one screwdriver that comes with the pack
The 1.5 mm hex key that comes with the pack
Masking tape (During the calibration process, multiple pieces from a single roll should be prepared in advance.)

 

Things to know beforehand

Understand the optical path structure of xTool P2

A laser beam is produced by the laser tube, reaches the first mirror, passes through the first optical path hole, reaches the second mirror, passes the second optical path hole, and then reaches the laser module through the third optical path hole, as shown in the following figure.

 

Software preparation

Refer to the following tutorial to prepare the software before testing.

 

How to do it

Note:
The video demonstrates just one example of offset cases. You'll need to select the corresponding scenario in the software and calibrate it based on the actual state.

First optical path hole test and mirror calibration

  • This video demonstrates testing the first optical path and guides you on calibrating the first mirror if necessary.
Stick the tape on the first optical path hole
Calibrate the first mirror to guide the first optical path

 

Second optical path hole test and mirror calibration

  • The video demonstrates how to test the second optical path and provides an example of calibrating it using one of the optical path offsets.
Stick the tape on the second optical path hole
Calibrate the first mirror to guide the second optical path

 

Third optical path hole test and mirror calibration

  • The video showcases the procedure for testing the third optical path and offers an instance of calibrating it with an optical path offset.
Stick the tape on the third optical path hole
Calibrate the second mirror to guide the third optical path
 
Was this page helpful?
127 out of 144 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Copyright © 2023 xTool All Rights Reserved.
Call Us
Service Time
Mon-Fri,9:00-18:30 PDT
Pre-sales Hotline
+1(970)638-7030
Customer Service Hotline
+1(775)587-7760
Email Us
Service Time
Mon-Fri,9:00-18:30 PDT
Pre-sales and shipping related
vicky@info.xtool.com
vicky@xtool.com
After-sales and shipping related
support@info.xtool.com
support@xtool.com
Technical Support
support@info.xtool.com(US)
support@xtool.com(US)
support.eu@xtool.com(EU)
support.uk@xtool.com(UK)
Brand Cooperation
If you want to cooperate with
xTool on causes like education,
public welfare, innovation, etc.,
or if you want to review our
machines, please email
partner@xtool.com
US headquarter
XTL US INC. 16035 Arrow Hwy.
Irwindale. CA91706
Copyright © 2023 xTool All Rights Reserved.