What are the technical specifications of xTool M1?

Below are the detailed technical specifications for both xTool M1 5w and 10w models.

FeaturexTool M1-10WxTool M1-5W
Laser Output Power10W5W
Light Spot Size (mm)0.08*0.08
Safety LevelClass I (FDA Certified)
Maximum Laser-cutting Capacity
 (under Laboratory Tests)
8mm Basswood Board3mm Basswood Board
Maximum Cuttable Material Thickness (Theoretical)*≤ 1.5mm (Varies by Material)
Maximum Engraving Speed (mm/s)250 (Bitmap Processing); 160 (Vector Processing)
Working Area (mm)385 * 300 (Laser Processing); 365 * 300 (Blade Cut Mode)
Engraving Accuracy (mm)0.01
Focus ModeAuto Focus
Connection MethodsWi-Fi / USB
Supported Operating SystemsWindows / macOS / Android / iOS
Noise Level (dB)<60
Weight (KG)9.8
Dimensions (mm)557*453*230
Exhaust Pipe Outer Diameter (mm)74
Supported File FormatsSVG, DXF, JPG, JPEG, PNG, BMP, TIF, CR2, etc.
Power Supply100~240V AC,50/60Hz
Machine Power (W)121.584

*Please note: The maximum cuttable material thickness of 1.5mm is a theoretical maximum and is subject to the material, the adhesive strength of the cutting mat, and the blade tip angle.

 

Why is the red dot on my M1 laser device not centered?

It is common for some users to notice that the red dot on the M1’s baseplate is not centered. This is a normal condition and should not be considered a cause for concern. It is important to clarify that the red dot serves solely for the automatic measurement function. Below is a detailed explanation:

M1 Red Dot

Working Principle

  • The red dot is emitted from the upper-right corner of M1 and projected onto the baseplate at an angle (refer to the image below). This angled projection means the position of the red dot will vary depending on the material's thickness. During the "Auto-Measure" process, the camera analyzes the red dot's position to calculate material thickness, with a typical accuracy of ±1mm, which falls within acceptable production standards.
M1 Red Projection

Below are two scenarios that explain the observed red dot discrepancies:

 

Scenarios:

  • Red Dot Discrepancy Between Material Surface and Baseplate:
    • This variation is normal and expected due to the angled projection.
  • Red Dot Discrepancy on Baseplate but Normal Measurement Value:
    • If the measured value is outside the range of 3 ± 1mm, it may indicate potential issues with the "Auto-Measure" function. Perform the verification procedure below to diagnose the presence of the issues and determine whether further calibration is entailed. If so, follow the instructions in the tutorial link below.
    • Please consult: How to Calibrate the Auto-Measure for xTool M1 for advice.

 

Verification Steps:

  1. Place a flat 3mm basswood board on the baseplate.
  2. Use the "Auto-measure" feature to check the material thickness in xTool Creative Space (XCS).
  3. If the result is within 3 ± 1mm, the machine is functioning properly.
Auto-measure Feature

📌 Important Note
The red dot's position may vary slightly due to minor assembly tolerances, but this does not affect M1’s performance or functionality. Each machine is calibrated before leaving the factory to ensure precise operation.

Preview
Was this page helpful?
3 out of 3 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Copyright © 2024 xTool All Rights Reserved.
Call Us
Telephone
Pre-sales : +1(970)638-7030
After-sales : +1(775)587-7760
Email
Pre-sales : vicky@info.xtool.com
After-sales : support@info.xtool.com
Service Time
Mon-Fri : 7:00 am - 5:30 pm (PT)
Sat-Sun : 8:30 am - 5:30 pm (PT)
Copyright © 2024 xTool All Rights Reserved.