đź’ˇRationale for optical path calibration
1. Check for Deviation: Detect whether the laser path through the third optical path hole has deviated. If there is no deviation, calibration is not needed. If there is a deviation, calibrate the machine’s optical path.
2. First Optical Path Hole: If the laser is not detected through the third optical path hole, check the laser tube at the first optical path hole to ensure the tube is functioning correctly.
3. Second Optical Path Hole: If the laser passes through the first optical path hole correctly, check and calibrate the laser position at the second optical path hole.
4. Third Optical Path Hole: After calibrating the laser position at the second optical path hole, check and calibrate the laser position at the third optical path hole.
Tools | Description |
2-in-1 screwdriver with cross & 2.5mm hex head (Included in the P2S package) | |
1.5mm Hex key |
⚠️Caution
Before conducting optical path inspection and testing, ensure that the first and second mirrors are properly installed by pressing them fully into their slots.
If this article or video doesn't effectively assist you in resolving the issue, please let us know by clicking the “No” button in the “Was this page helpful?” section below, and leave your feedback in the pop-up suggestion box. Our knowledge base team will review it and consider it for future updates.
If you need any human assistance, please create a ticket by clicking the “Submit a Ticket” button in the “Help Ticket” section below. Our service team will get back to you in 1 business day via E-mail.