When the H indicator lights up on your laser device's state display screen during operation, it signals a high-temperature warning. The machine remains usable but needs temperature monitoring. If it surpasses 45°C, it will stop working.
Optimal Operating Temperature:
Improving Cooling Efficiency:
Switching from antifreeze-containing cooling water to 100% distilled water enhances the cooling system's efficiency. Distilled water, with superior thermal conductivity and fewer impurities, improves heat absorption and transfer.
Documentation feedback
Help improve this content by providing feedback. If this content did not meet your requirements, select "No" in the "Was this page helpful?" section below. Include specific details about what was unclear or missing in the pop-up suggestion box. Feedback submissions are reviewed by xTool technical writers to enhance future documentation.