Troubleshoot "Measurement Failed" During Density Measuring for xTool P2
Updated Nov 21,2024
Updated Nov 21,2024
Issue Description
When you want to mark the coordinates on a curved surface for measurement density, you may see a pop-up error message as shown below:
#1 Check if your material is supported
Adjust the placement angle of the material or replace it.
Only smooth surfaces with an angle lower than 45 degrees are supported.
#2 Check the properties of the material
Highly reflective, transparent, or dark black materials will affect the measurement.
Please replace the material or apply a coating on the material before measuring.
#3 Check the measurement range
When processing curved surfaces, make sure that the material is placed within 25 mm above and 50 mm below the top surface of the slats.
If none of the above works
If you have any questions, collect the troubleshooting steps you have taken and the product SN, shoot a video of the issue, and contact us for further assistance at: support@xtool.com.