💡 Tips:
Control box | |
USB cable | |
Power adapter & power cable | |
CO2 gas bottles | |
Tube | |
Tube adapter | |
User manual |
01 - One-press fire extinguishing button 02 - Status switching button 03 - Working state indicator 04 - Gas bottle replacement indicator 05 - USB port 06 - Smart switch test button 07 - Power port 08 - Tube fitting 09 - Device port 10 - Working / Test mode switch 11 - Test state indicator |
(1) Prepare the tube and tube adapter and insert the tube into the tube adapter.
(2) Insert one end of the tube into the tube port on the fire safety set. Then insert the other end of the tube into the fire safety set port of xTool S1.
⚠️ When you install the tube, install it to the tube fitting port instead of other ports. Or it may damage the laser module.
Prepare the power adapter and power cable.
Connect the power cable to the power port on the fire safety set. Then plug the connector into the socket to connect a power supply.
Prepare the USB cable.
(2) When you connect to the power supply and turn on xTool S1, a beep sound sounds from xTool S1. It means the fire safety set connects to xTool S1 successfully.
💡 Power off the fire safety set and unplug the USB cable before installing CO2 gas bottles. Or you may touch the one-press fire extinguishing button by mistake to trigger the action of fire extinguishing.
(1) Unplug the power cable and USB cable. Hold the middle part of the control box and remove the upper cover.
(2)Put the gas bottles into holes and rotate them clockwise to tighten them. Then put the upper cover back to the control box.
(3) Reconnect the control box and USB cable and power on the control box.
(1) Make sure the control box connects to the power supply. Toggle the Working / Test mode switch to enter the working state.
The test state indicator goes off and the working state indicator blinks.
(2) Press the Status switching button on the control box, then the working state indicator turns solid green, indicating that the fire safety set enters the working state.
💡 Tips:
If the fire safety set works in the working state, the sensor indicators blink and the buzzer sounds when a flame is detected.
Slow sound: small flame detected, triggering an alarm only
Rapid sound: large flame detected, triggering an alarm and the action of fire extinguishing.
⚠️ Attention:
When the fire safety set works in the working state, you can press the button to manually trigger the action of fire extinguishing.
During fire extinguishing, the gas is released twice at an interval of 20 s, please wait for the process to complete before you touch the control box.
After performing the action of fire extinguishing, the gas bottle replacement indicator is solid on, indicating that you need to replace the gas bottles. You need to purchase new gas bottles for replacement.
💡 The CO2 gas bottles are not included.
If you use 2 gas bottles, install them on a diagonal, for example, installing them on holes A, and then install two empty gas bottles on the other diagonal.
After replacing the gas bottles, you can connect the control box of the fire safety set to the power supply to use it.