xTool F2 Ultra UV Auto Focus Issue
Issue description
A pop-up message indicating that the auto-focus failed appears at the top of the screen, or the measured thickness of the material to be processed deviates by more than 0.5 mm from the actual one.

Troubleshooting
During the automatic distance measurement process, if you adjust the laser module using physical buttons (manual focus) or click the reset function in the device settings, the automatic measurement process will stop. Therefore, please do not press any buttons on the controller during automatic distance measurement.
Step 1: Perform second calibration
Refer to this guide to perform a second calibration.
Step 2: Place the material correctly
The automatic distance measurement requires placing the material on the blue focus point. If the material is not placed correctly, automatic focusing may fail or may be inaccurate.

Step 3: Use compatible materials
This function is not suitable for transparent, semi-transparent, reflective, fluffy (cotton), or light-absorbing (black acrylic) materials. Please make sure the material is compatible.
Tip: You can place or wrap a thin, easily visible material over the surface to help with automatic distance measurement.
Step 4: Secure the connection
The device needs to take photos and send them to xTool Studio for image processing. If the device is disconnected or the Wi-Fi network is slow, the image transmission may fail, leading to automatic focusing failure.
Still experiencing issues?
Should the issue persist after completing the preceding steps, submit a ticket via the "Submit a Ticket" button in the "Help Ticket" section below. The standard response time for xTool Customer Service is one business day.
For a prompt resolution, please include the following details:
- Issue description: A detailed explanation of the observed problem.
- Video evidence: Attach a video demonstrating the issue, where applicable.
- Troubleshooting performed: Any troubleshooting steps you have already attempted, along with their results.
This information is crucial for xTool technical support engineers to provide timely assistance.
Documentation feedback
Help improve this content by providing feedback. If this content did not meet your requirements, select "No" in the "Was this page helpful?" section below. Include specific details about what was unclear or missing in the pop-up suggestion box. Feedback submissions are reviewed by xTool technical writers to enhance future documentation.