How to perform first calibration with first correct software

Article author
support
  • Updated

1.Download and unzip the first correct GUI file attached.  
(The software download  is at the bottom the article)

 

2.open the software FirstCorrect_GUI.exe.

mceclip0.png

3.Place the 3mm steel plate and a big white paper (80g 530x380mm) one by one in the machine. 

Note:

1.If there are no steel plates, flat 3mm basswood boards can work instead like above picture shown

2.If there are no a big white paper , three A3 white paper could be used.

3.make sure all spot could show on  papers completely,The calibration point position is beyond the white paper, please adjust the white paper position and replace it with a new white paper

4.Make sure the white paper is flat and clean,It is best not to let the paper warp, you can glue the                     corners of the paper with adhesive paper

CatchDA96_06-02-12-57-46_.jpg

mceclip0.png

4.Please do the first calibration follow the order below:

mceclip2.png

 

1.Connect to the machine by clicking on Connect Laserbox.

2.Click on Process. Then the machine will start processing, please wait until it done.

Note: please keep the default setting on the software.

1.Click on Snapshot.

2.Click on Generate 

3.Click on Upload calibration file.

Note: If the icon of each step on left side turn green, means the step is successful.

mceclip2.png

 

5.After finishing the first calibration, please do not execute the position calibration in laserbox software.

 

 

 