Desktop smoke purifier | Pipe adapter |
Connection cable for xTool F1 | Connection cable for xTool M1 Ultra |
Power adapter & power cable |
Filter pack |
Pre-filter | Pipe |
User manual |
(1) Plug the pipe adapter of xTool M1 Ultra into the smoke inlet of the smoke purifier.
(2) Connect one end of the connection cable for xTool M1 Ultra to the reserved port on xTool M1 Ultra. And connect the other end to the other port on the smoke purifier.
π‘ Tips: This step is optional. You can decide whether to install the pipe included in the pack of the desktop smoke purifier according to your needs. |
To install the pipe adapter, stretch the end of the pipe first, and tighten the pipe adapter to the pipe clockwise.
π‘ Tips: There are 3 levels of power, including low, middle and high. If the laser module emits blue rays, it is recommended to select the high level. If the laser module emits infrared rays, it is recommended to select the middle or low level. |
Turn on the smoke purifier and select the power level by shifting the level adjustment switch.
The smoke purifier starts working when xTool M1 Ultra starts processing and continues working for a while long after xTool M1 Ultra stops processing, so as to purify the air.
The continued working time can be set on the XCS software.
π‘ Tips: When the smoke purifier is under the Constant mode and xTool M1 Ultra is detected, it automatically switches to the United mode. |
Indicator status | Buzzer status | Explanation |
Light on for 3 seconds, and light off | Three times | The device is powered on. |
The indicator of the united mode lights on. | Once | The device is working in united mode. |
The indicator of the constant mode lights on. |
Once | The device is working in constant mode. |
Blink rapidly |
Twice, at an interval of three seconds | The motor has been damaged. Please replace the filters in a timely manner or check whether something is blocking the smoke inlet. |
(1)Press two sides of the lid, open the lid and take out the pre-filter.
(2) Hold the strap of two sides up and take out the used filter pack.
(3) Put the new filter pack and pre-filter into the smoke purifier.
π‘ Tips: You can visit www.xtool.com to purchase the filter pack. |
(4) Close the lid.
π‘ Tips: Press the lid down and make sure the lid is installed properly. |
Problem: Under the United mode, the device is processing, but the purifier does not work. Why and what can I do?
Possible causes: The inlet gets blocked. Or There is something in the pipes. Or One or more filters fail to work after long-term use, which is indicated when the buzzer of the purifier sounds.
Solutions:
- Replace the filter(s). Replaceable filters are used in the product. When the buzzer of the machine sounds, you need to clean or replace the filters for the purifier. You can visit xtool.com to buy the filters you need.
- Power off the purifier, open the lid and check whether the inlet is blocked, and then check whether the outlet is choked.