Precautions for Replacing the Mirror Holder of xTool P2
Updated Nov 21,2023
Updated Nov 21,2023

About this guide

  • As a result of replacing the mirror holder (Pic 1), there may be a significant deviation in the level 2 laser path.
  • To avoid machine damage from laser offsets, it is recommended to recalibrate the laser path following the replacement.
  • Follow the steps below to verify any deviation in the laser path and learn how to calibrate it if necessary.
Pic 1

 

How to do it

#1 Check the second-level laser mirror

Check its installation:

  • Position the mirror's reflective surface inward, displaying alphanumeric characters outwardly.
  • The reflector notch should snap right into the lower left screw on the holder as shown in Pic 2.

Check the gap:

  • Examine the 1 mm gap (highlighted in red in Pic 3) between the adjustment plate and the fixing plate (highlighted in green in Pic 3).
  • If the two plates are too tight, loosen the fastening screws by turning them counterclockwise. Afterward, increase the gap by turning the adjustment screw clockwise until the gap measures roughly 1 mm.

Make sure that both of these checks are met before testing the level 2 laser path.

Pic 2
Pic 3
 

#2 Level 2 laser path test and calibration

  • Please refer to the 5:07 mark in the video below for testing and calibrating the level 2 laser path.
  • Specific timestamps for the test and calibration:
    • Level 2 laser path test: 5:07 - 6:08
    • Level 2 laser path calibration: 6:09 - 8:19

 

Contact us

If you have any questions, please record a video of the issue you encountered, gather the steps you have taken, and get in touch with xTool customer support team at support@xtool.com for further assistance.
 
Was this page helpful?
0 out of 0 found this helpful
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Help Ticket
Use this help ticket to submit your issue. We will respond within 1 business day
Submit a Ticket
Copyright © 2023 xTool All Rights Reserved.
Call Us
Service Time
Mon-Fri,9:00-18:30 PDT
Pre-sales Hotline
+1(970)638-7030
Customer Service Hotline
+1(775)587-7760
Email Us
Service Time
Mon-Fri,9:00-18:30 PDT
Pre-sales and shipping related
vicky@info.xtool.com
vicky@xtool.com
After-sales and shipping related
support@info.xtool.com
support@xtool.com
Technical Support
support@info.xtool.com(US)
support@xtool.com(US)
support.eu@xtool.com(EU)
support.uk@xtool.com(UK)
Brand Cooperation
If you want to cooperate with
xTool on causes like education,
public welfare, innovation, etc.,
or if you want to review our
machines, please email
partner@xtool.com
US headquarter
XTL US INC. 16035 Arrow Hwy.
Irwindale. CA91706
Copyright © 2023 xTool All Rights Reserved.